MCP4725
Microchip Digital-to-Analog Converter
Device Details
- Device address 98
- Address type 7-bit
- Little Endian
Registers
EEPROM
EEPROM * Address 96 * 12-bytes
If EEPROM is set, the saved voltage output will be loaded from power-on.
VOut
Output voltage * Address 64 * 12-bytes
Sets the output voltage relative to Vcc. VOut = (Vcc * value) / 4096. The output is a range between 0 and Vcc with steps of Vcc/4096. In a 3.3v system, each step is 800 microvolts.
Fields
#/registers/EEPROM/digitalOut
Digital (binary) output
- Bits 12:0
Field values
- 0: Ground
- 4095: Vcc (full power)
Set output as either fully on or fully off.
Functions
- getVOut: Read VOut from EEPROM as a function of Vcc.
- setVOut: Set VOut as a function of Vcc.
License
MCP4725 version 0.1.0. Generated from Cyanobyte Codegen version HEAD.
Contact Nick Felker.