MCP4725

Microchip Digital-to-Analog Converter

Device Details

  • Device address 98
  • Address type 7-bit
  • Little Endian

Registers

EEPROM

EEPROM * Address 96 * 12-bytes

If EEPROM is set, the saved voltage output will be loaded from power-on.

VOut

Output voltage * Address 64 * 12-bytes

Sets the output voltage relative to Vcc. VOut = (Vcc * value) / 4096. The output is a range between 0 and Vcc with steps of Vcc/4096. In a 3.3v system, each step is 800 microvolts.

Fields

#/registers/EEPROM/digitalOut

Digital (binary) output

  • Bits 12:0

Field values

  • 0: Ground
  • 4095: Vcc (full power)

Set output as either fully on or fully off.

Functions

  • getVOut: Read VOut from EEPROM as a function of Vcc.
  • setVOut: Set VOut as a function of Vcc.

License

MCP4725 version 0.1.0. Generated from Cyanobyte Codegen version HEAD.

Contact Nick Felker.